White 1521 Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
8
INSTALLATION
Installation
Fig. 1 - Typical Connection of a Single Stage or Multi-Stage System
*Factory installed jumper between RH and RC
SYSTEM R RH RC C W/E
W2
Y
Y2
G O/B L
Single
Stage
24 VAC
Power
24 VAC
Power for
Heating
24 VAC
Power
for Cooling
24 VAC
Common
Required
Heat N/A Cool N/A Fan N/A System
Monitor
Multi
Stage
24 VAC
Power
24 VAC
Power
24 VAC
Power
Heat
mode
1
st
stage
Heat
mode
2
nd
stage
Cool
mode
1
st
stage
Cool
mode
2
nd
stage
CLASS II
Transformer
120 VAC
NEUTRAL
24 VAC
HOT
*
SYSTEM R RH RC C W/E
W2
Y
Y2
G O/B L
Heat
Pump
24 VAC
Power
24 VAC
Power for
Heating
24 VAC
Power
for Cooling
24 VAC
Common
Required
Aux /
Em
1
st
Stage
Aux /
Em
2
nd
Stage
1
st
Stage
Com
-
pres-
sor
2
nd
Stage
Com
-
pres-
sor
Fan Change
-
over
Valve
System
Monitor
CLASS II
Transformer
120 VAC
NEUTRAL
24 VAC
HOT
*
Fig. 2 - Typical Connection of Heat Pump System up to 4 Stages
Heat/2 Stages Cool
*Factory installed jumper between RH and RC
Note: Dual fuel systems W/E is fossil fuel 1
st
stage and W2 is fossil fuel 2
nd
stage.
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 31 32

Comments to this Manuals

No comments